SISTEM PENGISIANBATERAI (SEALED LEAD ACID)SLA MENGGUNAKAN INTERLEAVED BUCK CONVERTERDENGAN KAPASITOR KOPLING BERBASIS MIKROKONTROLER
Sari
type is very familiar because free maintenance and simple charging method, such as constant voltage or constant
current and combination of both methods to obtain the appropriate charging current standards. In addition,
charging power converter topologies to obtain high efficiency is also an option. This paper discusses SLA
battery charging system with a combination of constant current and constant voltage using Interleaved Buck DCDC Converter (IBC) with a coupling capacitorpower converters. This converter has a large step down voltage
conversion ratio, small ripple of currents and voltages and have a high efficiency.PWM control and charging
mode selectionATmega16 microcontroller is used as the control system. The experimental results for charging a
12V/17Ah battery showedthe charging system with a combination of constant current and constant voltage
worked properly. Maximum voltage of converter for charging was14.3V at 2Acharging current, 4% ripple of
current,2% ripple of voltage. Converter efficiency has reached 90.6%.
Teks Lengkap:
PDF (English)Referensi
Anuphappharadorn, Suratsawadee., Sukchai, Sukruedee.,
Sirisamphanwong, Chatchai., Ketjoy,Nipon. (2014):
Comparison the Economic Analysis of the Battery between
Lithium-ion and Lead-acid in PV Stand-alone
Application,Energy Procedia, Volume 56, 2014, pp 352-
Jorgustin, Ken.(2016):Battery State-Of-Charge For Voltage &
Specific Gravity, diakses dari
http://modernsurvivalblog.com/alternative-energy/batterystate-of-charge-chart/, pada tanggal 10 Februari 2016.
Kanta,Saowanee., Plangklang, Boonyang., Subsingha,Wanchai.
(2014):Design of a Bi-directional DC-DC 4 phase
Interleave converter forPV applications, Energy Procedia
, 2014, pp. 604 – 609
Koutroulis, E. & Kalaitzakis,K. (2004): Novel battery charging
regulation system for photovoltaic applications. IEE Proc.-
Electr. Power Appl., Vol. 151, No. 2, 2004.
Lakshmi, D., Zabiullah,S., Gopal, Venu.(2014):Improved Step
Down Conversion in Interleaved Buck Converter and Low
Switching Losses, International Journal Of Engineering
And Science Vol. 4 Issue 3(March 2014).
Lin, C.-C., Yang, L.-S., Wu, G.W. (2013):Study of a nonisolated bidirectional DC–DC converter, IET Power
Electronics, 2013, Vol. 6, Iss. 1, pp. 30-37.
Linden, David, and Reddy, Thomas B. (2002):Handbook of
Batteries, 3d ed. New York:McGraw-Hill, 2002, ISBN 0-
-135978-8.
Morgan,Tony. (2014):Guide to charging Sealed Lead Acid
batteries.,Silvertel. 2014.
Perez,Richard. (1993):Lead-Acid Battery State of Charge, Home
Power 36, 1993, pp. 66-70.
Pistoia, G., Wiaux, J.-P., Wolsky,S.P. (2001): Appendix A Most
common types of commercial batteries, Hand book of Used
Battery Collection and Recycling, Industrial Chemistry
Library,Volume 10, Elsevier, 2001, pp 329-339.
Ruetschi, Paul.(1993):Energy storage and the environment: the
role of battery technology,Journal of Power Sources,
Volume 42, Issues 1–2, 29 January 1993, Pp 1-7
Refbacks
- Saat ini tidak ada refbacks.